PROBLEM | CAUSE | CORRECTIVE ACTION | |
---|---|---|---|
Compressor is warm or hot & fan will not shut off. | 1 | Relay connection to compressor is loose. | Push relay on to compressor. |
2 | Relay is defective. | Replace relay. | |
3 | Refrigerant charge problem. | Contact service agent. | |
4 | Condenser fins in front of the fan are covered with debris. | Remove debris with compressed air or vacuum (may have caused overload, relay or compressor defect). | |
Compressor is room temperature. Fan runs continuously. | 1 | Possible open overload or relay. | Replace overload and relay. |
2 | Possible defective compressor. | Compressor needs to be replaced contact service agent. | |
3 | Condenser fins in front of the fan are covered with debris. | Remove debris with compressed air or vacuum (may have caused overload, relay, or compressor defect) | |
Compressor is room temperature & fan will not run. | 1 | Power lost to outlet. | Restore power to outlet. |
2 | Open cold control. | Replace cold control. | |
3 | Wire terminal not plugged in to cold control. | Locate correct terminal & plug in to cold control. | |
Compressor or inside of water cooler is hot. Fan is not running. | 1 | Fan is blocked by a tube. | Remove tube from fan. |
2 | Fan is defective. | Replace fan. | |
Compressor is making a loud knocking or grinding noise. | 1 | Compressor is defective | Compressor needs to be replaced. Contact service agent. |